Belden PRG11 CU PE MESSENGER - Coaxial 75 Ohm Cable |
Electrical performance |
Impedance (Ohm) |
75 ± 3 |
Capacitance (pF/m) |
55 ± 2 |
Velocity ratio (%) |
81.0 |
DC resistance |
Loop (Ohm/km) |
20 |
Inner conductor (Ohm/km) |
9.4 |
Attenuation at |
Frequency (MHz) |
5 |
10 |
50 |
100 |
200 |
230 |
300 |
400 |
600 |
800 |
860 |
1000 |
1350 |
1750 |
2150 |
2400 |
dB/100m |
0.9 |
1.2 |
2.7 |
3.9 |
5.7 |
6.1 |
7.0 |
8.2 |
10.2 |
12.0 |
12.5 |
13.6 |
16.1 |
18.7 |
20.9 |
22.5 |
Return Loss at |
5-470 MHz |
> 23 dB |
470-862 MHz |
> 20 dB |
862-2150 MHz |
> 18 dB |
Screening efficiency |
30-1000 MHz |
> 85 dB |
|
Construction and dimensions |
Material conductor |
Bare copper |
Diameter conductor |
1.55 mm |
Material dielectric |
Gas injected PE |
Diameter dielectric |
7.25±0.2 mm |
Type of foil |
Cu |
Overlap foil |
2 mm |
Braiding material |
Bare copper |
Braid coverage |
50 % |
Diameter outer conductor |
7.9±0.25 mm |
Sheath material |
PE |
Diameter sheath |
10.1±0.3 mm |
Catenary wire |
Zinc plated steel wires |
Diameter catenary wire |
4.6±0.2 mm |
Diameter width coax+catenary |
16.2±0.4 mm |
Min. setting radius |
100 mm |
Max. tensile strength |
4600 N |
Colour |
BLACK |
|
* Specification is subject to change without notice |